Page 1007 - A.J. Kitchen & Service
P. 1007
Fagor Professional Dishwashing
Water treatment
Manual water softeners
What you can achieve with treatment of water For hardness bigger than 5 HF / 3 HD.
Manual maintenance required.
Most of the water that comes out of the tap seems perfectly pure, Calcium and magnesium (hardness) are eliminated and the useful
however it may contain, as already mentioned, invisible contaminants. life of the equipment is significantly extended, reducing maintenance CODE DESCRIPTION CAPACITY OF REGENERATION (*) DIMENSIONS €
(mm)
Removing these elements has a decisive influence on water quality. interventions and the use of detergents and rinse aids.
19004690 DESCALING KIT 12 L. 1.050 litres between 2 regenerations Ø 185x560 mm -
SOFTNER REVERSE OSMOSIS 19004798 DESCALING KIT 16 L. 1.400 litres between 2 regenerations Ø 185x740 mm -
EXCELLENT WASH X
SAVING DETERGENTS X X
REDUCES GLASS AND CERAMICS WEAR X
PROTECTS THE MACHINE X X
Reverse osmosis
GOODBYE MANUAL DRYING X
GREAT ADVANTAGES OF REVERSE OSMOSIS:
- It reduces detergent use by up to 60% and rinse aid by 70-100%.
- It polishes plates, glasses and cutlery, obtaining a mark-free washing result since it does not require drying after the wash.
- It extends the life of glassware and dishes since it reduces corrosion.
Water treatment methods - It protects the machinery, extending its life.
Water treatment occurs mainly in two ways.
Inlet water conditions: - Flow: 120 l/h at 15°C.
SOFTNER REVERSE OSMOSIS - Type of inlet water: drinking water. - Recovery rate from 25% to 60%.
The result obtained by using the water softener is to eliminate the Thanks to the very high degree of filtration that characterizes reverse - Inlet water temperature: 5 °C - 35 °C. - Typical rejection rate: 95 %.
calcium Ca2+ and magnesium Mg2+ ions, responsible for the hardness osmosis machines, it is possible to obtain water with high quality - Minimum flow: 400 l/h. - Electrical connection 230V ~
50/60Hz.
of the water. This effectively prevents the formation of encrustations characteristics.Water, passing through one or more membraness, is - Supply pressure: 1.5-6 bar. - Prefilter that reduces and eliminates
which over time reduce the performance of the machines and cause deprived not only of the elements that determine its hardness, but also - Maximum conductivity of inlet water turbidity, chlorine, tastes and
malfunctions. of all substances contaminants, responsible, for example, for unwanted water: 1200 μS / cm. smells. Its nominal filtration rate is 5
odors and flavors. - Maximum inlet water hardness: up microns.
to 35°f with pH below 8.5 and up to
27°f with pH above 8.5. - Easy to install.
For excellent results and long maintenance intervals, the two - As of 10°dH 15°dH or 27°f, we - Prefilter change alarm.
technologies can be combined. recommend installing a water - Water leak alarm.
softening system prior to - Low-pressure alarm at system
osmosis to prevent blockage of the entrance.
membrane. - Manual bypass valve.
- High-flow reverse osmosis system.
- Vertical or horizontal installation.
ONLY VALID FOR: AD-505, AD-125, COP-404, COP-504 y COP-144
MODEL CODE FLOW 15ºC NUMBER OF VOLTAGE (V) FREQUENCY (HZ) POWER (KW) DIMENSIONS (mm) €
(L/H) MEMBRANES
REVO-120 19076763 120 2 230 50 / 60 0,33 145 x 560 x 455 -
MODEL CODE DESCRIPTION €
PREF-PACK6 19076764 Pack of 6 units of rapid-connection cartridges with extruded carbon block filter -
203 204