Page 3116 - A.J. Kitchen & Service
P. 3116
TECHNICAL DATA UC-S UC-S Energy UC-S Excellence-i / UC-S Excellence-iPlus
General data UC-S UC-M UC-L UC-XL 654
460 603
Tank capacity l 9.5 15.3 15.3 15.3
Rack dimensions mm 400 x 400 500 x 500 500 x 500 500 x 500 / 500 x 540 309
Clear entry height mm 309 309 404 404 725-760 715 309 810-845 800 820-855 810
Wash pump kW 0.6 0.6 0.6 0.6 423
328
Noise emission dB(A) max. 55
IP protection class with plastic rear cover IPX3 IPX3 IPX3 – 637b 940
10a 617 10a 10a
IP protection class with CN rear panel IPX5 IPX5 IPX5 IPX5
Weight net / gross kg 59 / 68 64 / 74 69 / 79 69 / 79
with Energy kg 64 / 73 70 / 80 75 / 85 75 / 85
with Excellence-i kg 79 / 88 85 / 95 – –
UC-M UC-M Energy UC-M Excellence-i / UC-M Excellence-iPlus
Max. inlet water temperature °C 60 (Energy: 20 / Excellence-i: 35)
657
Required water flow pressure bar / kPA 1.0 – 10.0 / 100 – 1.000
600 603
with Energy bar / kPA 1.5 – 10.0 / 150 – 1.000
with UC Excellence-i bar / kPA 1.4 – 10.0 / 140 – 1.000 309 309
725-760 715 810-845 800 820-855 810
Specific data depending on software Glasses Dishes Bistro Cutlery 423
328
Theoretical capacity Standard * 1 Racks / h 22 / 32 / 48 24 / 28 / 40 28 / 32 / 40 11
637b 940
Theoretical capacity Short programme * 1 Racks / h 77 66 66 21 10a 617 10a 10a
Standard: 2.0 Standard: 2.0 Standard: 2.0 Standard: 3.2
Rinse water volume per l Eco: 1.8 Eco: 1.8 Eco: 1.8 Eco: 2.9
wash cycle * UC-S
2
Cool: 3.4
Standard: 2.2 Standard: 2.2 Standard: 2.2 Standard: 3.4
Rinse water volume per UC-L UC-L Energy
l Eco: 2.0 Eco: 2.0 Eco: 2.0 Eco: 3.1
wash cycle * UC-M, -L, -XL
2
Cool: 3.4 657
62 600 603
Tank temperature °C 62 62 69 Note The following dimensions must be
Cool: 55 considered when installing the machine
65 in a recess:
Rinse water temperature °C 85 65 – 85 85 404 895
Cool: * 3 820-855 810 905-940
Rinse water temperature Energy * 4 °C 65 65 65 65 Height: + 5 mm
328 Width: + 10 mm
Depth: + 5 mm
637b 1034
10a 617 10a
a) Removing the feet reduces the machine
height by 10 mm.
ELECTRICAL DATA b) Without the build-in storage tanks for
UC-XL UC-XL Energy detergent and rinse aid, the depth reduces by
Voltage Fuse Total connected load * Total connected load Cool * 5 Countries 20 mm for all machines.
5
protection Tank heating 1.8 kW Tank heating 2.5 kW 691
Boiler heating 4.9 kW Boiler heating 4.9 kW 600 637 Further information can be found in our
10 A 6.0 kW – installation diagram.
380 V – 415 V, 3N~, 50 Hz / 60 Hz
16 A 7.9 kW 6.1 kW 404
10 A 1.8 kW – Worldwide 820-855 810 905-940 895
13 A 2.6 kW –
220 V – 240 V, 1N~, 50 Hz / 60 Hz 328
16 A 3.2 kW 3.4 kW
20 A 4.1 kW 4.2 kW 671b 1068
10a 10a
230 V, 2~, 50 Hz / 60 Hz 16 A 3.0 kW – 651
Belgium
230 V, 3~, 50 Hz / 60 Hz 25 A 7.3 kW –
200 V, 2~, 50 Hz / 60 Hz 20 A 3.3 kW – * Depending on local conditions (inlet water temperature / electrical supply), the values stated here can be reduced.
1
Japan
200 V, 3~, 50 Hz / 60 Hz 25 A 6.9 kW – * Non-binding information. The actual rinse water volume may vary depending on the on-site conditions.
2
* Depends on the inlet water temperature, switchable from 65 °C.
3
* Inlet water temperature < 20 °C.
4
* The actual connected load varies depending on the mains voltage.
5
16 TECHNICAL DATA 17 TECHNICAL DATA