Fagor Professional                                                                                                    Foodservice | Cooking


            Fixed cylindrical boiling pans










                                                                                                                                    MODEL                  CODE             POWER           CAPACITY         DIMENSIONS       €
                                                                                                                                                                             (kW)              (l)             (mm)
                                                                                                                                   CYLINRICAL GAS BOILING PANS
                                                                                                                                   Directly heated gas
                                                                                                                                   MCG-300               19003043            39               300          1290x1391x950      -
                                                                                                                                   MCG-500               19001445            55               500         1390x1479x1020      -
                                                                                                                                   Directly pressure heated gas
                                                                                                                                   MCG-300 A             19003041            39               300          1290x1391x950      -
                                                                                                                                   MCG-500 A             19001446            55               500         1390x1479x1020      -
                                                                                                                                   Indirectly heated gas
                                                                                                                                   MCIG-200              19003078            39               200          1090x1195x900      -
                                                                                                                                   MCIG-300              19001448            48               300          1290x1391x950      -
                                                                                                                                   MCIG-500              19003079            55               500         1390x1479x1020      -
                                                                                                                                   Indirectly pressure heated gas
                                                                                                                                   MCIG-200 A            19001447            39               200          1090x1195x900      -
                                                                                                                                   MCIG-300 A            19001449            48               300          1290x1391x950      -
                                                                                                                                   MCIG-500 A            19001450            55               500         1390x1479x1020      -
                                                                                                                                    ELECTRIC CYLINDRICAL BOILING PANS
                                                                                                                                   Indirectly heated electric
                                                                                                                                   MCIE-200              19003076            24               200          1060x1000x900      -
            General Characteristics                                                                                                MCIE-300              19001443            36               300          1260x1200x950      -
                                                                                                                                   MCIE-500              19003077            48               500         1360x1300x1000      -
                                                                                                                                   Indirectly pressure heated electric
            - Boiling pan with cylindrical structure    - Front drainage tap with an insulated         overheating or insufficient water.
              and recipient, suitable for placement      athermic handle.     - Water control in the double wall with              MCIE-200 A            19001442            24               200          1060x1000x900      -
              in transit areas with reduced dimensions     - Gauge for controlling pressure inside the       maximum/minimum taps and an       MCIE-300 A  19003040          36               300          1260x1200x950      -
              where appliances with sharp edges         double wall.            automatic water load option.                       MCIE-500 A            19001444            48               500         1360x1300x1000
              and surfaces may cause ergonomic and                                                                                                                                                                            -
              movement problems, allowing it to be used    - Manual valve for emptying air in order to      - Standard operating voltage of 400V-3N-
              comfortably from different angles.    depressurise the chamber during heating.    50Hz
            - Well with AISI-316 stainless steel bottom    - Water is added to the well through a tap      INDIRECT STEAM:
              with a thickness of between 20/10 and        with a moveable outlet.  - Heated by steam (from the user’s
              40/10, suitable for products that are    - Heating:               connection) through a valve that allows
              particularly acidic.           GAS:                               steam to be added gradually into the liner.
            - AISI-304 stainless steel walls with a       - High-performance stainless-steel tubular     - Indirect heating equipment: pressure
              thickness of between 20/10 and 40/10.        burners.             control in the double wall through a safety        Options                                              Accesories
              Double wall in indirect versions.  - Manual piezoelectric ignition and pilot         valve set to 0.5 bar, a manual depression
            - AISI-304 stainless steel cover with a         flame.              valve and a gauge.                                          MODEL    CODE  DESCRIPTION           €             MODEL     CODE  DESCRIPTION     €
              thickness of 15/10, balance springs and an    - Smoke extraction grille.  - The pressure or autoclave versions allow
              athermic handle.                                                  the cooking cycles to speed up through the                  GF-M   19084528  Drainage tap with 2” AISI-316   -  CM-2200  19084524  Kit 2 1/2 baskets for   -
                                                                                                                                                                                                               200-litre boiling pan
                                                                                                                                                           clamp connection
            - Supporting structure in AISI-304 stainless    - Tap with safety valve and thermocouples      day. They are fitted with a silicone rubber
                                               (direct version).
              steel.                                                            airtight joint and clamps to hermetically                   VM-M   19084529  2.5” AISI-304 butterfly valve   -  CM-2300  19084525  Kit 2 1/2 baskets for   -
                                                                                close it and a safety valve set to 0.05 bar.
            - Satin AISI-304 exterior coating.  INDIRECT ELECTRIC:                                                                                         ISO DN50                                            300-litre boiling pan
            - Adjustable stainless-steel feet.  - Heated by elements immersed in                                                            TD-M   19084539  Flexible tube with shower  -      CM-4300  19084526  Kit 4 1/4 baskets for   -
                                               Incoloy alloy with adjustable power via an
            - Heat insulation guaranteed by high-density      energy variator.                                                                                                                                 300-litre boiling pan
              ceramic fibre plates.          - Safety thermostat which ensures that the                                                                    Device for automatic                                Kit 4 1/4 baskets for
            - Tank drainage hole with a removable filter.    machine does not operate in the event of                                       DA-M   19084530  drainage of air from double   -   CM-4500  19084527  500-litre boiling pan  -
                                                                                                                                                           wall
                                                                                                                                 *          CENA-M  19084531  Electronic control of water   -
                                                                                                                                                           load in double wall
                                                                                                                                                           Electronic control of water
                                                                                                                                            CECA-M  19084532  load in the well with display   -
                                                                                                                                                           and volumetric probe